| |
|
This transducer selection
guide is intended to offer assistance in identifying transducer models that may best suit the requirement. Click on the desired Model number to view complete details regarding
transducer specifications and capabilities. |
|
| Level Transducers (Submersible) |
Model |
|
Accuracy |
|
Description |
|
Photo |
|
Minimum
Full Scale |
|
Maximum
Full Scale |
|
Output |
|
735
730
720
710
700 |
|
±0.05% FS
±0.10% FS
±0.25% FS
±0.50% FS
±1.00% FS |
|
General purpose,
analog output |
|
 |
|
5 feet
(1.5
meters) |
|
700 feet
(210 meters) |
|
4-20 mA, 0-5 VDC,
mV |
|
335
330
320 |
|
±0.05% FS
±0.10% FS
±0.25% FS |
|
Small bore,
analog output |
|
 |
|
5 feet
(1.5
meters) |
|
700 feet
(210 meters) |
|
4-20 mA, 0-5 VDC,
mV |
|
|
750 |
|
±0.25% FS |
|
Non-fouling,
2.75" diaphragm,
analog output |
|
 |
|
10 feet
(3
meters) |
|
115 feet
(35 meters) |
|
4-20 mA, 0-5 VDC |
|
|
705 |
|
±0.25% FS |
|
Non-fouling,
0.90" diaphragm,
analog output |
|
|
|
6 feet
(2
meters) |
|
115 feet
(35 meters) |
|
4-20 mA, 0-5 VDC |
|
|
300DS |
|
±0.50% FS |
|
Deep water,
small bore,
analog output |
|
|
|
700 feet
(210
meters) |
|
8535 feet
(2600 meters) |
|
4-20 mA, 0-5 VDC,
mV |
|
173
169 |
|
±0.10% FS
±0.25% FS |
|
Datalogger
specific, analog output |
|
 |
|
5 feet
(1.5
meters) |
|
700 feet
(210 meters) |
|
mV |
|
|
126
116
|
|
±0.10% FS
±0.30% TEB
±0.25% FS
±0.30% TEB |
|
Datalogger
specific, 6 wire analog output |
|
|
|
5 feet
(1.5
meters) |
|
700 feet
(210 meters) |
|
mV with voltage
sense |
|
|
343
342
|
|
±0.05% FS
±0.25% TEB
±0.10% FS
±0.25% TEB |
|
ASIC-based,
small bore,
analog output |
|
|
|
5 feet
(1.5
meters) |
|
230 feet
(70 meters) |
|
4-20 mA, 0-5 VDC |
|
|
772 |
|
±0.10% FS
±0.25% TEB |
|
ASIC-based,
field re-rangeable,
analog output |
|
 |
|
5 feet
(1.5
meters) |
|
230 feet
(70 meters) |
|
4-20 mA, 0-5 VDC |
|
|
500 |
|
±0.05% TEB |
|
Microcomputer-based,
digital output |
|
|
|
5 feet
(1.5
meters) |
|
230 feet
(70 meters) |
|
SDI-12 |
|
|
waterMONITOR
|
|
±0.05% TEB |
|
Embedded
datalogger, small bore,
digital output |
|
 |
|
10 feet
(3
meters) |
|
692 feet
(210 meters) |
|
RS-485 with
SDI-12 protocol |
|
| Pressure Transducers (Non-Submersible) |
Model |
|
Accuracy |
|
Description |
|
Photo |
|
Minimum
Full Scale |
|
Maximum
Full Scale |
|
Output |
|
35
30
27
28 |
|
±0.05% FS
±0.10% FS
±0.25% FS
±0.50% FS |
|
General purpose,
analog output |
|
 |
|
2 psi
(14 kPa) |
|
300 psi
(2070 kPa) |
|
4-20 mA, 0-5 VDC,
mV |
|
|
200 |
|
±0.50% FS |
|
High pressure,
pressure output |
|
 |
|
2000 psi
(13.8 mPa) |
|
15,000 psi
(103.4 mPa) |
|
4-20 mA, 0-5 VDC,
mV |
|
Download KPSI Level and Transducer Selection Guide (PDF)

|
|