Parameter |
735(6)
|
730(6)
|
720 |
710 |
700 |
Units |
Comments |
LEVEL RANGES |
| Full Scale
Level Ranges (8) |
5 thru 700
(1.5 thru 210)
|
2.5 thru 700
(0.75 thru 210) |
ft H2O
(m H2O) |
for vented gage
reference |
| N/A |
35 thru 700
(10 thru 210) |
10 thru 700
(3 thru 210) |
ft H2O
(m H2O) |
for sealed gage
reference |
| N/A |
35 thru 700
(10 thru 210) |
ft H2O
(m H2O) |
for absolute
reference |
| Proof Pressure |
1.5 |
x FS |
 |
| Burst Pressure |
2.0 |
x FS |
 |
STATIC PERFORMANCE |
| Static Accuracy (1) |
±0.05 |
±0.10 |
±0.25 |
±0.50 |
±1.00 |
% FSO |
BFSL |
| Resolution |
Infinitesimal |
|
 |
ENVIRONMENTAL |
| Wetted Materials |
316 SS or Titanium; Delrin®;
polyurethane or Viton® |
 |
Delrin® and Viton® are registered trademarks of DuPont. |
| Compensated
Temp Range |
0 to 50 |
ºC |
|
| Thermal Error
(2) |
±0.05 (4) |
%FSO/ºC |
worst case over
compensated temperature range |
| Operating Temp Range |
-20 to 60 |
ºC |
 |
| Protection
Rating |
IP 68, NEMA 6P |
|
|
ELECTRICAL |
| Excitation |
9 -
30
2.5 - 10 |
VDC |
for mA, VDC and non-ratiometric
mV output
for ratiometric mV output |
| Input Current |
20
3.5 |
mA max |
for mA output
for VDC output |
| Output (9) |
4 -
20
0 - 5
0 - 100 (3)
2.5 - 10 |
mA
VDC
mV
mV / V |
options available (7)
non-ratiometric
ratiometric (range dependent) |
| Zero Offset |
±0.20 (5)
< 0.1
±0.6 |
mA
VDC
mV |
for mA output
for VDC output
for mV output |
| Output
Impedance |
See Loop Resistance diagram
page 7 of datasheet
< 10
3000 - 5000 |
ohm |
for mA output
for VDC output
for mV output |
| Insulation Resistance |
100 |
mega ohm |
at 50 VDC |
| Circuit Protection |
Polarity, surge/shorted output |
 |
 |
PHYSICAL |
| Approximate Weight |
0.44 (198)
0.05 (79) |
lbs (g)
lbs/ft (g/m) |
transducer
cable |
Cable
Jacket Material
Pull Strength
Number of Conductors
Conductor Size |
Polyurethane (std)
Tefzel® (opt)
200 (90)
4
22 |
lbs (kg)
AWG |
Tefzel®, Teflon® and
Kevlar® are registered trademarks of DuPont. |
| Cable Seal |
Molded Polyurethane
Viton® Gland |
|
for polyurethane
cable
for Tefzel® cable |
TEMPERATURE OUTPUT OPTION (NOT INTRINSIC
SAFETY APPROVED) |
| Temperature Range |
0 to 50
-20 to 60 |
ºC |
available for 4-20 mA output versions only |
| Output Signal |
4-20 |
mA |
 |
| Temperature Measurement Accuracy |
±4 |
ºC |
 |
LIGHTNING PROTECTION (OPTIONAL) |
| Life Expectancy |
> 1000 operations |
|
|
| Peak Clamping
Voltage |
36 volts |
|
|
| Response Time |
< 10 nsecs |
|
|