Esterline Pressure Systems Logo header spacer Pressure Systems Site Map Pressure Systems Home
 
 

KPSI Series 340 ASIC-Based Small Bore Submersible Level Transducer: Speceifications

link arrow  return to Series 340 main product page

 
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
 
Parameter
343
342
Units
Comments

LEVEL RANGES

Full Scale Level Ranges (1)  10 thru 230
(3 thru 70)

ft H2O
(m H2O)

for vented gage reference
N/A 35 thru 230
(10 thru 70)
ft H2O
(m H2O)
for sealed gage or absolute reference
Proof Pressure
1.5
x FS
Burst Pressure
2.0
x FS
STATIC PERFORMANCE
Static Accuracy 

±0.05

±0.1
% FSO
BFSL method
Total Error Band (2)
±0.25

%FS TEB

Total Error from BFSL
Resolution
Infinitesimal

%FS

ENVIRONMENTAL

Wetted Materials 
316 SS or Titanium;
polyurethane or Viton®
 Viton® is a registered trademark of DuPont.
Compensated Temp Range 

-20 to 60

ºC
Operating Temp Range
-20 to 60
ºC
Protection Rating

IP 68, NEMA 6P

   

ELECTRICAL

Excitation

9-30

VDC

for mA and VDC output
Input Current

20
3.5

mA max

for mA output
for VDC output
Output

4 - 20
0 - 5

mA
VDC

Zero Offset

±0.12
< 0.1

mA
VDC

for mA output
for VDC output
Output Impedence

See Loop Resistance diagram page 5
510

ohm

for mA output
for VDC output
Insulation Resistance

100

mega ohm

at 50 VDC
Circuit Protection

Polarity, surge/shorted output

PHYSICAL

Approximate Weight
0.50 (224)
0.05 (79)

lbs (g)
lbs/ft (g/m)

transducer
cable
Cable
 
Jacket Material


  Pull Strength

  Number of Conductors
 
Conductor Size

Polyurethane (std)
Tefzel® (opt)

200 (90)

4

22




lbs (kg)



AWG
Tefzel®, Teflon® and Kevlar® are registered trademarks of DuPont.
Cable Seal

Molded polyurethane
Viton® Gland

  for polyurethane cable
for Tefzel® cable
   
(1) Intermediate level ranges are available.
(2) Total Error Band (TEB) includes the combined errors due to nonlinearity, hysteresis,  nonrepeatability, and thermal effects over the compensated temperature range per ISA S51.1.
 

Specifications subject to change without notice.

 


 
Pressure Systems
34 Research Drive
Hampton, VA 23666
800.678.7226
KPSI Selection Guide Quality Policy
ISO-9001:2000
Receive E-Newsletter
IPC Member Logo WEEE/RoHS Statement
WEEE/RoHS
Statement
 


Home | Environmental Products | Industrial Products | Aerospace Products | Buy Now
KPSI Level and Pressure Selection Guide | Quartzonix Pressure Standard | NetScanner System | System 8400 |