Esterline Pressure Systems Logo header spacer Pressure Systems Site Map Pressure Systems Home
 
 

KPSI Series 300DS Small Bore Submersible Level Transducer: Specifications

link arrow  return to Series 300ds main product page
 
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
 
Parameter
300DS
Units
Comments

LEVEL RANGES

Full Scale Level Ranges (1)

700 thru 4614
(210 thru 1408)

ft H2O
(m H2O)

sealed gage reference
Proof Pressure
1.5
x FS
Burst Pressure
2.0
x FS
STATIC PERFORMANCE
Static Accuracy (2)
±0.5
% FSO
BFSL method
Resolution
Infinitesimal

ENVIRONMENTAL

Wetted Materials
316 SS; Delrin®; Viton®
Delrin® and Viton® are registered trademarks of DuPont.
Compensated Temp Range
0 to 50
ºC
Thermal Error (3)
±0.05
%FSO/ºC
worst case over compensated temperature range
Operating Temp Range

-20 to 60

0 to 50

ºC

ºC

when using polyurethane cable


when using ETFE cable (5)

Protection Rating
IP 68, NEMA 6P
   

ELECTRICAL

Excitation
9 - 30
VDC
for mA and VDC output
Input Current
20
3.5
mA max
for mA output
for VDC output
Output
4 - 20
0 - 5
mA
VDC

options available (4)
Zero Offset
±0.12
< 0.25
mA
VDC
for mA output
for VDC output
Output Impedance

See Loop Resistance diagram page 5 of datasheet
< 10

ohm

for mA output
for VDC output
Insulation Resistance
100
mega ohm at 50 VDC
Circuit Protection
Polarity, surge/shorted output

PHYSICAL

Approximate Weight

0.63 (285)
0.05 (79)

lbs (g)
lbs/ft (g/m)
transducer
cable
Cable
 
Jacket Material


  Pull Strength

  Number of Conductors
 
Conductor Size

Polyurethane (std)
ETFE (6) (opt)

200 (90)

4

22





lbs (kg)



AWG


Tefzel®, Teflon® and Kevlar® are registered trademarks of DuPont.
Cable Seal
Viton® Gland
  for polyurethane cable
for ETFE cable
   
(1) Intermediate level ranges are available.
(2) Static accuracy includes the combined errors due to nonlinearity, hysteresis and nonrepeatability on a Best Fit Straight Line (BFSL) basis, at 25ºC per ISA S51.1.
(3) Thermal error is the maximum allowable deviation from the Best Fit Straight Line due to a change in temperature, per ISA S51.1.
(4) Custom VDC output levels can be provided up to 2.5 VDC less than the excitation supply voltage.
(5) -20ºC to 50ºC for level ranges <= 100 ft (70m) H2O when using ETFE cable.
(6)

 ETFE is a fluoropolymer (Teflon® derivative) material, Tefzel® or equivalent



Specifications subject to change without notice.


 



 
Pressure Systems
34 Research Drive
Hampton, VA 23666
800.678.7226
KPSI Selection Guide Quality Policy
ISO-9001:2000
Receive E-Newsletter
IPC Member Logo WEEE/RoHS Statement
WEEE/RoHS
Statement
 


Home | Environmental Products | Industrial Products | Aerospace Products | Buy Now
KPSI Level and Pressure Selection Guide | Quartzonix Pressure Standard | NetScanner System | System 8400 |